Model No.: Ex-proof solenoid coil 0940

 
Anti-proof solenoid valve coils 4V210 series coils are designed for 4V210 Solenoid valves. All solenoids of this system have the s

 

Anti-proof solenoid valve coils 4V210 series coils are designed for 4V210 Solenoid valves. All solenoids of this system have the stable power and good insulation , could be able to adapt to the bad environment .

The Insulation Class can reach ExmbII4.

 

The product is developed to be used in ambients with temperature range from -50°C to +50°C, and it has 

a power consumption of 3.8W for type T4 and 3W for type T5.

The coil fits all standard operators 3/2 or 2/2 way NC or NO , threaded or flange types.

All main voltages are available.

Other specific voltage and power could be customized as your request.

 

 

Specifications:

 

Brand name : NIJIA

Model number : Ex-proof Solenoid valves

Voltage : DC 12V-24V  AC24V-380V

Working Medium : Air,Water,Oil

Operating Method : Direct action

Working Temperature : -50~50°C

Connection type : Fly Lead-type

Qualification Certificate : CNEX13.2864

 

Explosion Protection Class:

 

 

Specific marking of explosion protection.

II

Group II – Electrical apparatus for places with a potentially

explosive atmosphere, other than mines susceptible to fire dump.

2

Category 2 – see the board below.

G

Explosive gas atmospheres.

D

Explosive atmosphere in the presence of combustible dust.

Ex

The symbol Ex which indicates that the electrical apparatus corresponds to one of the

 protection type (EN 60079-0).

mb

Type of protection for gas – encapsulation “m”, level “mb”.

tb

Type of protection for explosive dust atmospheres –protection by enclosure.

IIC

Electrical equipment of Group II is subdivided according to

the nature of the explosive gas atmospheres – IIC, a typical gas is hydrogen.

IIIC

Electrical equipment of Group III is subdivided according to the nature of the explosive 

dust atmospheres – IIIC, conductive dust.

T5 or T4

Temperature Class. T5 or T4.

Gb

Equipment   protection   level   [EPL]   for   explosive   gas atmospheres.

Db

Equipment   protection   level   [EPL]   for   explosive   dust atmospheres.

IP66

The degrees of protection provided by an enclosure against

ingress  of solid  foreign objects,  dust  (first  number)  and water (second number).

 

 

Drawings:

 

 

 

 

Competitive Advantage:

 

1. Professional factory and excellent team.

2. Best service from the whole company.

3. High and stable quality.

4. Adequate inventory and quick delivery time.

5. Good package in order to void the problems in transportation.

 

bigPhoto
 Mr. Ricky

Tel: 86-574-88871448
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Ningbo Nijia Electronics Technology Company [China (Mainland)]


Business Type:Manufacturer
City: Ningbo
Province/State: Zhejiang
Country/Region: China (Mainland)

You May Like:

Product (83)